ansible / ansible.builtin / v2.4.2.0-1 / module / bigip_monitor_http Manages F5 BIG-IP LTM http monitors | "added in version" 1.4 of ansible.builtin" Authors: Serge van Ginderachter (@srvg), Tim Rupp (@caphrim007) preview | supported by communityansible.builtin.bigip_monitor_http (v2.4.2.0-1) — module
pip
Install with pip install ansible==2.4.2.0.post1
Manages F5 BIG-IP LTM monitors via iControl SOAP API
- name: BIGIP F5 | Create HTTP Monitor bigip_monitor_http: state: "present" server: "lb.mydomain.com" user: "admin" password: "secret" name: "my_http_monitor" send: "http string to send" receive: "http string to receive" delegate_to: localhost
- name: BIGIP F5 | Remove HTTP Monitor bigip_monitor_http: state: "absent" server: "lb.mydomain.com" user: "admin" password: "secret" name: "my_http_monitor" delegate_to: localhost
ip: default: none description: - IP address part of the ipport definition. The default API setting is "0.0.0.0". required: false name: aliases: - monitor default: null description: - Monitor name required: true port: default: none description: - Port address part of the ip/port definition. The default API setting is 0. required: false send: default: none description: - The send string for the monitor call required: true state: choices: - present - absent default: present description: - Monitor state required: false parent: default: http description: - The parent template of this monitor template required: false receive: default: none description: - The receive string for the monitor call required: true timeout: default: none description: - The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this number to any number you want, however, it should be 3 times the interval number of seconds plus 1 second. The default API setting is 16. required: false interval: default: none description: - The interval specifying how frequently the monitor instance of this template will run. By default, this interval is used for up and down states. The default API setting is 5. required: false provider: description: - A dict object containing connection details. suboptions: auth_provider: description: - Configures the auth provider for to obtain authentication tokens from the remote device. - This option is really used when working with BIG-IQ devices. type: str no_f5_teem: default: false description: - If C(yes), TEEM telemetry data is not sent to F5. - You may omit this option by setting the environment variable C(F5_TELEMETRY_OFF). - Previously used variable C(F5_TEEM) is deprecated as its name was confusing. type: bool password: aliases: - pass - pwd description: - The password for the user account used to connect to the BIG-IP or the BIG-IQ. - You may omit this option by setting the environment variable C(F5_PASSWORD). required: true type: str server: description: - The BIG-IP host or the BIG-IQ host. - You may omit this option by setting the environment variable C(F5_SERVER). required: true type: str server_port: default: 443 description: - The BIG-IP server port. - You may omit this option by setting the environment variable C(F5_SERVER_PORT). type: int timeout: description: - Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error. type: int transport: choices: - rest default: rest description: - Configures the transport connection to use when connecting to the remote device. type: str user: description: - The username to connect to the BIG-IP or the BIG-IQ. This user must have administrative privileges on the device. - You may omit this option by setting the environment variable C(F5_USER). required: true type: str validate_certs: default: true description: - If C(no), SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates. - You may omit this option by setting the environment variable C(F5_VALIDATE_CERTS). type: bool type: dict version_added: 1.0.0 version_added_collection: f5networks.f5_modules partition: default: Common description: - Partition for the monitor required: false time_until_up: default: none description: - Specifies the amount of time in seconds after the first successful response before a node will be marked up. A value of 0 will cause a node to be marked up immediately after a valid response is received from the node. The default API setting is 0. required: false receive_disable: default: none description: - The receive disable string for the monitor call required: true parent_partition: default: Common description: - Partition for the parent monitor required: false