ansible / ansible.builtin / v2.9.25 / module / cpm_serial_port_config Set Serial port parameters in WTI OOB and PDU devices | "added in version" 2.9 of ansible.builtin" Authors: Western Telematic Inc. (@wtinetworkgear) preview | supported by communityansible.builtin.cpm_serial_port_config (v2.9.25) — module
pip
Install with pip install ansible==2.9.25
Set Serial port parameters in WTI OOB and PDU devices
# Set Serial Port Parameters - name: Set the Port Parameters for port 2 of a WTI device cpm_serial_port_config: cpm_url: "nonexist.wti.com" cpm_username: "super" cpm_password: "super" use_https: true validate_certs: false port: "2" portname: "RouterLabel" baud: "7" handshake: "1" stopbits: "0" parity: "0" mode: "0" cmd: "0" seq: "1" tout: "1" echo: "0" break_allow: "0" logoff: "^H"
# Set Serial Port Port Name and Baud Rate Parameters - name: Set New port name and baud rate (115k) for port 4 of a WTI device cpm_serial_port_config: cpm_url: "nonexist.wti.com" cpm_username: "super" cpm_password: "super" use_https: true validate_certs: false port: "4" portname: "NewPortName1" baud: "8"
cmd: choices: - 0 - 1 description: - This is the Admin Mode to assign to the port, 0=Deny, 1=Permit. required: false seq: choices: - 1 - 2 - 3 description: - This is the type of Sequence Disconnect to assign to the port, 0=Three Characters (before and after), 1=One Character Only, 2=Off required: false baud: choices: - 0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 description: - This is the baud rate to assign to the port. - 0=300, 1=1200, 2=2400, 3=4800, 4=9600, 5=19200, 6=38400, 7=57600, 8=115200, 9=230400, 10=460800 required: false echo: description: -This is the command echo parameter to assign to the port, 0=Off, 1=On required: false mode: choices: - 0 - 1 - 2 - 3 - 4 description: - This is the port mode to assign to the port, 0=Any-to-Any. 1=Passive, 2=Buffer, 3=Modem, 4=ModemPPP. required: false port: description: - This is the port number that is getting the action performed on. required: true type: int tout: choices: - 0 - 1 - 2 - 3 - 4 - 5 description: - This is the Port Activity Timeout to assign to the port, 0=Off, 1=5 Min, 2=15 Min, 3=30 Min, 4=90 Min, 5=1 Min. required: false logoff: description: - This is the logout character to assign to the port - If preceded by a ^ character, the sequence will be a control character. Used if seq is set to 0 or 1 required: false parity: choices: - 0 - 1 - 2 - 3 - 4 - 5 description: - This is the parity to assign to the port, 0=7-None, 1=7-Even, 2=7-Odd, 3=8-None, 4=8-Even, 5=8-Odd. required: false cpm_url: description: - This is the URL of the WTI device to send the module. required: true portname: description: - This is the Name of the Port that is displayed. required: false stopbits: choices: - 0 - 1 description: - This is the stop bits to assign to the port, 0=1 Stop Bit, 1=2 Stop Bit. required: false handshake: choices: - 0 - 1 - 2 - 3 description: - This is the handshake to assign to the port, 0=None, 1=XON/XOFF, 2=RTS/CTS, 3=Both. required: false use_https: default: true description: - Designates to use an https connection or http connection. required: false type: bool use_proxy: default: false description: Flag to control if the lookup will observe HTTP proxy environment variables when present. required: false type: bool break_allow: description: - This is if the break character is allowed to be passed through the port, 0=Off, 1=On required: false cpm_password: description: - This is the Password of the WTI device to send the module. required: true cpm_username: description: - This is the Username of the WTI device to send the module. required: true validate_certs: default: true description: - If false, SSL certificates will not be validated. This should only be used - on personally controlled sites using self-signed certificates. required: false type: bool
data: description: The output JSON returned from the commands sent returned: always type: str